HP / Keysight / Agilent N5412A Overview
To make measurements with the N5412A SAS compliance test software, you also will need a method of connecting to the SAS compliance interface on the electrical mating surfaces of your SAS connector. Agilent currently provides a full set of compliance test fixtures for the SFF-8482, SAS x2 internal drive/backplane connector interfaces. The N5421A SAS SFF-8482 compliance test fixture kit offers connectivity from the SFF-8482 primary and secondary transmitter and receiver differential ports to SMA for connection to Agilent Infiniium 80000, 90000 and 90000 X Series ultra-high-performance oscilloscopes. The N5421A kit also includes the TX and RX transient circuit test loads. Each of these test circuits is defined in Section 5.7.2, Zero-length test load, in the Serial Attached SCSI - 2.1 (SAS-2.1) Specification, Revision 4, September 17, 2009.
Automation:
- Test setup wizard guides you through test selection, configuration, connection, execution, and results reporting
- Measurement connection setups are displayed
- Oscilloscope setup is automatically configured for each test
- Test results report documents test configuration, measurements made, pass/fail status, margin analysis, and waveforms
Standards Supported:
- Complete set of SAS IT/CT and IR/CR transmitter electrical tests for 1.5Gb/s and 3.0Gb/s
- Support OOB signaling tests for 6.0Gb/s
- Test definitions on UNH-IOL standard
- Trials test capability for quick comparison of multiple port configurations
Requirements:
- N5421A SFF-8482 Test Fixture