HP / Keysight / Agilent N3306A Overview
Testing multiple output dc power supplies and dc-dc converters can be very time consuming if each output must be tested sequentially. If measurements are being made through a MUX using one DMM, this is what will happen. Using the built-in measurement capabilities of the N3300A electronic loads, all outputs can be measured simultaneously. Alternatively, multiple single output power sources can be tested simultaneously.
A single GPIB address is all you need for complete control and read-back of the N3306A load module within a single N3300A or N3301A mainframe. The N3306A electronic load provides fast operation and the accurate programming and read-back needed for high-volume DC power supply test systems.
Input Ratings
- Current: 0 - 120 A
- Voltage: 0 - 60 V
- Maximum Power: 600 W
Constant Current Mode
- Low Range/High Range: 12 A/120 A
- Regulation: 10 mA
- Low Range Accuracy: 0.1% + 15 mA
- High Range Accuracy: 0.1% + 37.5 mA
Constant Voltage Mode
- Low Range/High Range: 6 V/60 V
- Regulation: 20 mV
- Low Range Accuracy: 0.1% + 3 mV
- High Range Accuracy: 0.1% + 8 mV
Constant Resistance Mode
- Range 1 (I >10% of current rating): 0.017-1 ?
- Range 2 (I >1% of current rating): 0.9-10 ?
- Range 3 (I >0.1% of current rating): 9-100 ?
- Range 4 (I >0.01% of current rating): 90-1000 ?