| B10 |
External generator control for FSP, FSU, FSG, FSQ, ESU, ESCI, ESPI and for retrofit of |
| B12 |
Output attenuator for tracking generator for FSU, FSQ |
| B16 |
LAN interface |
| B18 |
Removable hard disk for spectrum analyzer family FSU with Win XP (factory installed) |
| B19 |
Second hard disk for FSU-B18 analyzer firmware for FSU with Win XP included |
| B20 |
Extended environment specification. Random vibr. 1.9G RMS, 0-55°C (not retrofittable) |
| B25 |
Electronic attenuator 0 to 30 dB, Preamplifier 20 dB, 10MHz - 3.6 GHz for FSU, FSQ |
| B27 |
FM output, 10 MHz bandwidth |
| B28 |
Trigger port for FSP,FSQ,FSU; for indication of trigger conditions |
| B33 |
USB mass memory write protection, disables writing to USB memory sticks (ex factory only) |
| B4 |
OCXO 10 MHz aging/year: 0.35*10E-7 for FSU, FSQ, FSMR |
| B5 |
Output for low phase noise 640MHz reference signal for FSU3, FSU8, FSQ3 und FSQ8 |
| B73 |
Vector signal analysis for FSU demodulation bandwidth 8 MHz (FSU), broadband demodulation hardware included |
| B85 |
Extended displayed average noise level spec.for option preamplifier R&S®FSU-B25 (for R&S®FSU3 / FSU8 only. R&S®FSU-B25 |
| B87 |
Extended linearity specification for specific channel filters |
| B88 |
RF hardware option 1 FSU8/FSQ8 |
| B9 |
Tracking generator for FSU and FSQ, 100 kHz - 3.6 GHz |
| C3 |
Three years of depot calibration coverage based on the R&S recommended calibration interval - includes test data. The first calibration is included with product delivery with 2 additional depot calibration(s). |
| C5 |
Five years of calibration coverage based on the R&S recommended calibration interval - includes test data. The first calibration is included with product delivery with 4 additional depot calibration(s). |
| D3 |
TEST DATA |
| DCV-2 |
Documentation of calibration values |
| DCV-ZP |
Printout of DCV (additional, in combination with DCV-Option only) |
| DKD |
FSU3 DKD (ISO17025) calibration incl. ISO 9000 calibration (order only with device) |
| FS-B33 |
USB mass memory write protection, disables writing to USB memory sticks (ex factory only) |
| FS-K110 |
Analysis of TETRA II / TEDS signals (for FSQ, FSU with option FSU-B73) |
| FS-K15 |
VOR/ILS measurements for FSMR |
| FS-K30 |
Application firmware for noise figure and gain measurements for FSMR, FSP, FSQ, FSU |
| FS-K40 |
Application firmware for phase noise measurements for FSMR, FSP, FSQ, FSU |
| FS-K5 |
Application firmware GSM/EDGE tests for FSP, FSU, FSQ |
| FS-K5U |
Upgrade of R&S®FS-K5 to R&S®FS-K10, GSM/EDGE/EDGE Evolution measurement application, |
| FS-K7 |
FM demodulator, allows measurement of FM specific parameters (for FMU, FSP, FSU) |
| FS-K72 |
Application firmware 3GPP-FDD BTS transmitter test for FSMR, FSP, FSU, FSQ |
| FS-K73 |
Application firmware 3GPP-FDD UE transmitter test for FSMR, FSP, FSU, FSQ |
| FS-K73+ |
3GPP HSPA+ UE transmitter test, application firmware (for R&S®FSP/FSQ/FSU with WinXP, |
| FS-K74 |
3GPP HSDPA base station test application firmware for FSMR, FSU, FSP, FSQ |
| FS-K74+ |
3GPP HSPA plus, base station test. Application firmware (for FSP, FSQ, FSU, FSG with WinXP; |
| FS-K76 |
3GPP TD-SCDMA base station test; application firmware for FSMR, FSP, FSQ, FSU |
| FS-K77 |
3GPP TD-SCDMA mobile station test; application firmware for FSMR, FSP, FSQ, FSU |
| FS-K8 |
Application firmware for Bluetooth measurement on FSP, FSU and FSQ |
| FS-K82 |
CDMA2000/1xEV-DV base station test application firmware for FSMR, FSP, FSU, FSQ |
| FS-K83 |
CDMA2000/1xEV-DV mobile station application firmware for FSMR, FSP, FSQ, FSU |
| FS-K84 |
1xEV-DO base station test application firmware for FSMR, FSU, FSP, FSQ |
| FS-K85 |
1xEV-DO mobile station test application firmware for FSMR, FSP, FSQ, FSU |
| FS-K9 |
Measurements with NRP power sensors NRPZ11/Z21/Z22/Z23/Z24/Z51/Z55/Z91 requires NRP-Z3 or NRP-Z4 |
| FSP-B10 |
External generator control for FSP, FSU, FSG, FSQ, ESU, ESCI, ESPI and for retrofit of |
| FSP-B28 |
Trigger port for FSP,FSQ,FSU; for indication of trigger conditions |
| K10 |
GSM/EDGE/EDGE Evolution Measurement Appl (for FSG/FSQ/FSU) |
| K15 |
VOR/ILS measurements for FSMR |
| K30 |
Application firmware for noise figure and gain measurements for FSMR, FSP, FSQ, FSU |
| K4 |
PHASE NOISE MSMT |
| K40 |
Application firmware for phase noise measurements for FSMR, FSP, FSQ, FSU |
| K5 |
Application firmware GSM/EDGE tests for FSP, FSU, FSQ |
| K5U |
Upgrade of FS-K5 to FS-K10, GSM/EDGE/EDGE Evolution Measurement Appl (for FSG, FSQ, FSU) |
| K7 |
FM demodulator, allows measurement of FM specific parameters (for FMU, FSP, FSU) |
| K72 |
Application firmware 3GPP-FDD BTS transmitter test for FSMR, FSP, FSU, FSQ |
| K73 |
Application firmware 3GPP-FDD UE transmitter test for FSMR, FSP, FSU, FSQ |
| K73+ |
3GPP HSPA+ UE transmitter test, application firmware (for FSMR, FSP, FSQ, FSU, FSUP, |
| K74 |
3GPP HSDPA base station test application firmware for FSMR, FSU, FSP, FSQ |
| K74+ |
3GPP HSPA plus, base station test. Application firmware (for FSP, FSQ, FSU, FSG; |
| K76 |
3GPP TD-SCDMA base station test; application firmware for FSMR, FSP, FSQ, FSU |
| K77 |
3GPP TD-SCDMA mobile station test; application firmware for FSMR, FSP, FSQ, FSU |
| K8 |
Application firmware for Bluetooth measurement on FSP, FSU and FSQ |
| K82 |
CDMA2000/1xEV-DV base station test application firmware for FSMR, FSP, FSU, FSQ |
| K83 |
CDMA2000/1xEV-DV mobile station application firmware for FSMR, FSP, FSQ, FSU |
| K84 |
1xEV-DO base station test application firmware for FSMR, FSU, FSP, FSQ |
| K85 |
1xEV-DO mobile station test application firmware for FSMR, FSP, FSQ, FSU |
| K9 |
Measurements with NRP power sensors NRP-Z11/Z21/Z22/Z23/Z24/Z51/Z55/Z91 requires NRP-Z3 or NRP-Z4 |
| R3 |
Three years of depot repair coverage, including recalibration and test data if necessary to complete the repair. First year of repair coverage is provided by the 12-month new product warranty. |
| R5 |
Five years of depot repair coverage, including re-calibration if necessary to complete the repair. First year of repair coverage is provided by the 12-month new product warranty. |
| Z1 |
Service kit for spectrum analyzer family FSU |
| ZZA-411 |
19" adapter, 4 HU, 1/1 for BW2000 cabinets |