| B1 |
Ruggedized housing with adjustable carrying handle (not retrofittable, not for |
| B10 |
External generator control |
| B17 |
Digital baseband interface, retrofittable, detector board Rev. 05.01 required, |
| B18 |
Solid state drive, 8GB, including analyzer firmware, replaces standard hard drive |
| B19 |
Second hard disk incl. analyzer firmware for exchange against standard hard disk |
| B21 |
LO/IF Ports for External Mixers |
| B22 |
RF Preamplifier 20 dB, 9 kHz to 7 GHz |
| B25 |
Electronic attenuator, 1 dB steps |
| B29 |
Frequency extension to 20Hz (retrofittable in service center) |
| B3 |
AM/FM demodulator for listening; includes loudspeaker, plug for headphone and volume control |
| B4 |
OCXO, precision frequency reference, aging per year: 0.1 ppm |
| B5 |
Additional interfaces. IF/Video/AM-FM-demod. output, AUX port, trigger output, 2 additional USB(A) |
| B70 |
Extension to 40MHz signal analysis bandwidth |
| B9 |
Tracking generator. 100 kHz - 7 GHz (FSV7 / FSV13 / FSV30); 100 kHz - 3.6 GHz (FSV3) |
| C3 |
Three years of Factory Standard depot calibration coverage based on the R&S recommended calibration interval - includes test data. The first calibration is included with product delivery with 2 additional depot calibration(s). |
| C5 |
Five years of Factory Standard depot calibration coverage based on the R&S recommended calibration interval - includes test data. The first calibration is included with product delivery with 4 additional depot calibration(s). |
| DCV-2 |
Documentation of calibration values |
| DCV-ZP |
Printout of DCV (additional, in combination with DCV-Option only) |
| DKD |
FSV7 DKD (ISO17025) calibration incl. ISO 9000 calibration (order only with device) |
| FS-B33 |
USB mass memory write protection, disables writing to USB memory sticks (ex factory only) |
| K10 |
Analysis of GSM, EDGE and EDGE evolution signals |
| K100 |
Analysis of EUTRA/LTE FDD downlink signals |
| K101 |
Analysis of EUTRA/LTE FDD uplink signals |
| K102 |
EUTRA/LTE Downlink MIMO measurement application (FSV-K100 or FSV-K104 required) |
| K104 |
Analysis of EUTRA/LTE TDD downlink signals (for FSV) |
| K105 |
Analysis of EUTRA/LTE TDD uplink signals (for FSV) |
| K14 |
Spectrogram measurement application |
| K30 |
Noise figure and gain measurements (Preamplifier R&S®FSV-B22 required) |
| K40 |
Phase noise measurement application |
| K54 |
EMI application for diagnostic of RF interference with spectrum analyzers R&S®FSV and |
| K7 |
Analog modulation analysis for AM, FM, PM |
| K70 |
Vector signal analysis application for modulation analysis of digital modulated single carrier signals |
| K72 |
Analysis of 3GPP-FDD base station signals incl. HSPA+ |
| K73 |
3GPP-FDD UE analysis incl. HSPA |
| K76 |
3GPP TD-SCDMA BTS measurements application |
| K77 |
3GPP TD-SCDMA UE measurement application |
| K7S |
FM stereo measurement application, measurement of L, R, M, S and pilot dev, Crosstalk, THB |
| K8 |
Bluetooth/EDR measurement application (software license) |
| K82 |
Analysis of CDMA2000 base station signals |
| K83 |
CDMA2000 MS measurement application (software license) |
| K84 |
Analysis of 1xEV-DO base station signals |
| K85 |
1xEV-DO MS measurement application (software license) |
| K9 |
Power sensor measurement with NRP power sensors |
| K91 |
Analysis of WLAN 802.11a,b,g,j signals |
| K91n |
Extension of FSV-K91 to 802.11n (FSV-K91 required) |
| K93 |
Analysis of Wimax 802.16 SISO signals |
| R3 |
Three years of depot repair coverage, including Factory Standard recalibration and test data if necessary to complete the repair. First year of repair coverage is provided by the 12-month new product warranty. |
| R5 |
Five years of depot repair coverage, including Factory Standard recalibration and test data if necessary to complete the repair. First year of repair coverage is provided by the 12-month new product warranty. |
| U1 |
Upgrade to dual core CPU processor |
| ZZA-478 |
19" adapter, 4 HU, 7/8 for BW2000 cabinets |